Nikon SoRa Spinning Disk
- Nikon Ti2-E inverted microscope
- Hamamatsu ORCA Fusion BT sCMOS camera
- Yokogawa SoRa CSU-W1 spinning disk unit
- Super-resolution, confocal and widefield fluorescence imaging modes
- 4x, 10x, 20x, 25x silicone oil, 40x, 60x oil and 100x oil objective lenses
- Mad City Labs 500 mm piezo stage
- Tokai Hit stage top incubator for live cell imaging
- PFS perfect focus control for live cell imaging
- 7 diode laser lines: 405, 445, 488, 514, 561, 594, and 640 nm


Zeiss LSM 880 Airyscan
- Zeiss AxioObserver Z1 inverted microscope
- GaAsP spectral detector for confocal imaging
- 4 color Airyscan “super-resolution” module
- Airyscan FAST for faster super-resolution imaging
- 5x, 10x, 20x, 25x multi-immersion, 40x oil, 40x water, 63x water, 63x oil and 100x oil objective lenses
- Environmental encloser and Oko Labs stage top incubator for live cell imaging
- Definite Focus for live cell imaging
- Motorized stage with z-piezo for fast Z-stack image acquisition
- 7 laser lines: Argon (458, 488, 514 nm), three solid-state diode laser (405, 561, 594 nm) and one HeNe laser (633 nm)
Leica Stellaris 8 FLIM
- Leica DMi8 inverted microscope
- 5 HyD detectors (2 HyD S, 2 HyD X, and 1 HyD R)
- HyD X detectors are used for FLIM imaging
- Confocal and FALCON FLIM imaging modes
- TauGating imaging modes
- Galvo and Resonant Scanners
- 5x, 10x, 20x, 20x multi-immersion, 40x and 63x oil, and 63x water immersion objective lenses
- Oko Labs stage top incubator for live cell imaging
- Adaptive Focus Control for living cells
- Super Z Galvo Stage with extended z-range to 1.5 mm
- Navigator software module for extended field of view tile imaging
- 405nm diode laser and White Light Laser for excitation (selectable from 445 to 785 nm))
- Extended wavelength range for multi-channel and spectral confocal imaging
- FALCON FILM software module for fluorescence lifetime imaging, including FRET and Phasor plot analysis


Leica Stellaris 5 STED
- Leica inverted DMi8 microscope
- Confocal and and STED super-resolution, including Tau-STED and STED Xtend, imaging modes
- 4 HyD S detectors and 1 HyD X detector
- HyD X detector used for STED (Stimulated Emission Depletion) super-resolution imaging
- 5x, 10x, 20x, 20x multi-immersion, 40x oil, 63x oil and 100x oil objective lenses
- 100x oil plan-apochromat white objective lens for STED imaging
- 405nm diode laser and White Light Laser for excitation (485 to 685 nm) for confocal imaging
- 775nm STED depletion laser
- 10x, 20x and 40x objective lenses
- Tokai Hit stage top incubator for live cell imaging
- Adaptive Focus Control for live cell imaging
- Super Z Galvo Stage with extended z-range to 1.5 mm
- Navigator software module for extended field of view tile imaging